Georadis RT-50
Radiation Detection Monitor
The RT-50 is a state of the art gamma spectrum analyser which monitors and detects presence of radiation in metals, metals by-products, geological samples, construction materials, environmental commodities, food and many other materials. Floor standing and easy to operate, the RT-50 spectrum analyser is an indispensable part of any analytical laboratory, it rapidly detects and accurately measures extremely low levels of radioactive contamination. Used in such applications; Steel, scrap and other metal industries, geology and geophysics and the food and food processing industry.
-
Key Features
• High sensitivity
• Low operating costs and fast analyses.
• Ease of integration thanks to the SQL database, operable in networks.
• Wide range of sample containers, including Marinelli beakers.
• Sensitivity: Accurately measure the radioactivity in a given sample utilising a high sensitivity NaI(TI) scintillator. Measurement sensitivity 0.02 Bq/g.
• Multichannel Analyser: Self contained 1024 channel pulse amplitude analyser.
• Speed: Full sample analysis in only 5 mins.
• Ease of use: With little training the operator can use the graphic menu driven interface.
• Calibration: Optimised calibration eliminates long calibration times.
• Integration: All data stored in multiplatform open source SQL database to allow easy integration into customer’s own systems.
• Analysis Data: May be viewed, printed, archived or transferred to a network. -
Technical Specifications
• Detector: NaI(Tl) volume 0.35 l, 76 x 76 mm (3”x3”), with bi-alkali PMT Resolution better then 7.5% FWHM at 662 keV.
• High voltage: Supply range 500 – 1000 V digitally controlled
• Output: Positive impulses, rising time better then 0.5 µs, Amplitude linear range max +2.5 V, Bipolar Shaping, time constant 1 µs, Coarse gain HV controlled, Fine gain +/- 3 % in 1000 gain steps.
• Spectrum stabilization: Two point – offset and gain correction, 662 keV typ. at ch. 220, Precision +/- 0.1 ch.
• ADC: Approximation, double buffered, high speed and high linearity, Conversion time 1.5 µs 1024 channels down sampled from 65535, Digitally adjustable ADC zero +/- 80 mV, Digitally adjustable LLD range from 2nd – 30th channel, Automatic Dead time correction, precision better 0.25%.
• Nonlinearity: Integral max 0.1% of full scale within 95% of range, Differential max 3% of full scale within 95% of range.
• Communication interface: USB
• Reference source: 137Cs – 9 kBq (0.25 µCi).
• Power consumption: Power over USB, max 100 mA.
• Shielding: Steel, minimal thickness 85 mm, optionally Lead.
• Environmental: Operating temperature range 0°C to +40°C, Storage temperature range -20°C to +70°C.
• Size and weight: HxWxD 770 mm x 360 mm x 620 mm, Weight 410 kg (580 kg for Lead shield).
• Software requirements: Operating System Windows 2K, XP, Vista, Windows 7 or Linux with Kernel 2.6 Firebird SQL 2.0. - Documentation